Pre-running Inspection for Escalator Slow Train Debugging

Escalator Slow Train Debugging Check all safety circuit switches and reset. 501 board or PLC control can see the status of the LED corresponding to the line, and the corresponding switch can also be found by the line number according to the drawing.

Jan 11,2022

Pre-running Inspection

Check all safety circuit switches and reset. 501 board or PLC control can see the status of the LED corresponding to the line, and the corresponding switch can also be found by the line number according to the drawing.

The switch code corresponding to the drawing:

B36 Lower step disappearance monitoring

B37 Upper step disappearance monitoring

https://www.deysse.com/product/Escalator-Step%C2%A0Missing-Switch%C2%A0OEM%C2%A0XS8C1A1PAL01M12-GS00322008-223.html

S1 lower machine room emergency stop switch

S5 lower emergency stop switch  https://www.deysse.com/product/Escalator%C2%A0Emergency-Stop-Switch-GS00754001-702.html

S6 upper emergency stop switch  https://www.deysse.com/product/Escalator-Stop%C2%A0Switch-OEM-GBA177HA3-GS00422030-228.html

S60-61 Lower left and lower right comb plate impact switch

S62-63 Upper left and upper right comb plate impact switch

S65-66 Lower left and lower right handrail access switches

S67-68 Upper left and upper right handrail access switches

S70 Down Step Collapse Switch

S72 Upper Rung Collapse Switch

S75-76 Lower left and lower right step chain break switches

S145 Drive chain disconnect switch