    (Summary description)Escalator maintenance/revit content and requirements
    1. Understand the operation situation
    2. Set up the necessary maintenance and safety measures
    3. Give priority to handling emergencies
    4. Ladder road system maintenance
    5. Handrest system maintenance

    Escalator maintenance/revit content and requirements

    (Summary description)Escalator maintenance/revit content and requirements
    1. Understand the operation situation
    2. Set up the necessary maintenance and safety measures
    3. Give priority to handling emergencies
    4. Ladder road system maintenance
    5. Handrest system maintenance

    Information

    1. Understand the operation situation
    Technical regulations: ① Asks management and maintenance personnel about the operation and failure of escalators in this cycle;
                                        ② Check the escalator emergency repair record book.
    Inspection standards: ① To check the escalator fault and repair records;
                                       ② Access to maintenance records and work visa.

    2. Set up the necessary maintenance and safety measures
    Technical procedures: ① Maintenance, must first set up safety railings and "No Use" brand (up and down one);
                                        ② Power main switch can be cut off when necessary during maintenance;
                                        ③ If the maintenance ladder has been removed from the escalator, only the "maintenance box" is allowed to operate the escalator point at the maintenance speed, and no one is allowed to stand on the ladder;
                                        ④ Maintenance, the escalator must be checked without any debris and tools.
    Inspection standards: ① Requires that railings and standing plates can be eye-catching and effectively prevent people from entering the site;
                                       ② Ensure that the escalator is not started casually during maintenance;
                                       ③ Cut off the main switch in the escalator, and it can be locked if necessary.

    3. Give priority to handling emergencies
    Technical procedures: If the ladder is stopped due to a fault, remove the first fault.
    4. Ladder road system maintenance


    Technical procedures:① To remove 3 maintenance steps;
                                       ② Observe the cascade guide rail;
                                       ③ Check the cascade chain and the rising tension;
                                       ④ Checks for each cascade.
    Inspection standards: ① Is running smoothly, with no abnormal noise;
                                       ② Can align the center when entering the comb plate, and the depth of the comb teeth into the ladder groove meets the standard;
                                       ③ Checks the distance of the pole meets the criteria.

    5. Handrest system maintenance


    Technical specification: ① Check the entrance and exit of the armrest belt;
                                         ② Check whether the running speed of the armrest belt is synchronized with the step;
                                         ③ Check the surface and inside of the handrail belt for obvious signs of scars and friction;
                                         ④ Check the tension of the armrest strap
                                         ⑤ Check armrest pulley group and roller check friction wheel;
                                         ⑥ Cleaning work in the armrest strap watch.
    Inspection standards: ① Observe whether the armrest belt is in the middle of the entrance and exit when running up and down;
                                       ② Does the difference between operation speed and cascade operation meet the standard;
                                       ③ Check the handrail with no wire exposure and scar source, and exclude it;
                                       ④ Whether the tension of the armrest belt meets the standard or not, it can be adjusted;
                                       ⑤ The pulley group and rollers must be operated freely, smoothly and noise-free. Wear condition of the friction wheels.

    Keyword:

    Scan the QR code to read on your phone

    News More

    The

    The Elevator Show in Dubai, 16-18th Sep 2024

    The elevator exhibition was hold in Dubai, from 16th-18th September 2024. Our Deysse team participated in this exhibition. Please contact with us for spare parts.  
    2024-09-19
    The

    The World Elevator & Escalator Expo will be opened soon again in Shanghai.

    Please feel free to contact me if you'd like to book the entry tickets.
    2024-04-30
    3rd

    3rd ASCEN.TEC

    The 3rd “ASCEN.TEC”, the only specialized exhibition for the elevator industry in Greece, on June, 14 – 16, 2024, at the MEC exhibition center in Athens, Greece.
    2024-06-17

    EXTRA PAGES

  • share
  • share
  • share
  • share
  • MESSAGES

    Username used for comment:
    客户留言
    Description:
    Verification Code

    CONTACT US

    >  Contact Person: Sean Lee

    >  Phone: +86 20 8304 1994

    >  Fax: +86 20 8304 1967

    >  Whatsapp: +8613924192218

    >  Email: info@deysse.com

    >  Address: Room 2801-1,Jinhui Building,No.123 Jiefang South Road,Yuexiu District, Guangzhou, 510120 China

    Copyright © 2021 Guangzhou Deysse Elevator Fittings Co., Ltd All Rights Reserved.   privacy protection